| EX1394 LEAD POISONING PANEL |
| Specimen: |
10 mL (5 mL min.) aliquot of 24-hour urine was collected in a dark-colored container without preservatives. Ship frozen. DO NOT THAW. Record 24-hour volume on the test request form and urine container. Refrigerate during collection AND 4 mL (2 mL min.) whole blood from 1 metal-free Royal Blue Top (K2EDTA) tube. Ship refrigerated. DO NOT FREEZE. Use powderless gloves during specimen collection. |
| Stability: |
| Room |
Refrigerated |
Frozen |
| Ship at specified temperatures |
Ship at specified temperatures |
Ship at specified temperatures |
|
| Method: |
Column chromatography, AAS with Zeeman correction |
| Comment: |
Use only specified containers. If Gadolinium or Iodine containing contrast media has been administered, the specimen should not be collected for 96 hours. |
| Report: |
Contact us to know the TAT. |
| Usage: |
Industrial exposure to lead is seen in industries manufacturing lead-containing paints & ceramic glazes, batteries, water pipes & ammunition. Major exposure of the general population is through food & water. Lead-containing toys & paints are a primary source of lead exposure in children. The Centre for Disease Control (CDC) recommends universal screening of children from 6 months of age. 5- ALA concentrations are also a useful indicator for medium to high concentrations of lead exposure. |
| Doctor Specialty: |
Physician |
| Disease: |
Industrial diseases |
| Components: |
*5-Amino Levulinic Acid (5-ALA) *Lead Blood |
| Courier Charges: |
0.00 |
| Home Collection: |
Available (*T&C Apply) |
| Department: |
Biophysics |
| Pre Test Information: |
If Gadolinium or Iodine containing contrast media has been administered, the specimen should not be collected for 96 hours. |